Nerva
Nerva Apply for a pilot

Make your egocentric data 12× more useful by wearing a wristband.

Nerva is a wristband your capture team wears while recording. Its 16 EMG channels read the muscles that move the fingers and turn them into per-finger force and 20-DoF hand pose, synced to your head camera. In published wrist-EMG research, robots trained on demos with per-finger force succeeded 12× more often on squeeze tasks: 90% versus 7.5% without it.

He et al., ForceBand (2026): 72 of 80 squeeze trials with force, 6 of 80 for the best policy without.

Apply for a pilot Limited spots in the first cohort.
Pilots launch in November. Get better data, fast.
Figure 1. Hand pose decoded from 16-channel wrist EMG against motion capture, for a wearer outside the training set.

Specifications

Every value is labelled by its basis. Target: a design goal for Nerva’s first units, which have not been measured yet. Published: results from other teams’ wrist-EMG hardware or the physiology literature. Measured: our own run of an open model on public data.

ParameterConditionsValueUnitBasis
Signal
EMG channelsDry electrodes at the wrist16chTarget
EMG sample rate2000HzTarget
Hand pose
Joint anglesPer hand20DoFTarget
Joint angle errorWrist EMG only, wearers not in training set12.2°Published1
Joint angle errorStarting pose given, 328 windows, 36 held-out wearers; holding the starting pose scores 13.3°10.2°Measured2
Force
Fingertip force channels5chTarget
Fingertip force errorCalibrated wearer, per finger0.92NPublished3
Force error relative to videoAgainst video-based estimators< 0.5×Published3
Robot squeeze success, with force80 trials, same human demos90%Published3
Robot squeeze success, without forceBest force-free policy, 80 trials7.5%Published3
Signal quality
Skin temperature accuracyBeside the electrodes±0.2°CTarget
Skin humidity accuracySkin side of the band±2%RHTarget
Temperature and humidity rateLogged with every episode10HzTarget
Timing and setup
EMG onset before forceElectromechanical delay30–100msPublished4
CalibrationPer wearer, against fingertip force sensors15minPublished3
  1. Salter et al., emg2pose, NeurIPS 2024. Regression model, wearers outside the training set.
  2. Our evaluation of the released vemg2pose tracking weights on emg2pose sessions from wearers outside the training set (Figure 1).
  3. He et al., ForceBand: Learning Forceful Manipulation with sEMG, arXiv:2606.26093 (2026).
  4. Physiology literature on electromechanical delay.

Timing

Muscle activity starts 30 to 100 ms before fingertip force builds. Grasp onset and release come out of the EMG stream as timestamped events, before contact is visible on video.

Idealized timing: the EMG burst begins, fingertip force rises 30 to 100 ms later, and finger flexion follows. 30–100 ms EMG Fingertip force Finger flexion

Figure 2. Idealized timing, not measured data.

Output

One folder per episode, every stream aligned to the first frame of your video. Delivered as LeRobot, RLDS or plain HDF5.

episode_000123/
  head_rgb.mp4          # your camera, unchanged
  emg                   float32 [T, 16]   2000 Hz
  imu                   float32 [T, 9]     200 Hz
  hand_pose             float32 [T, 20]   rad, joint angles
  fingertip_force       float32 [T, 5]    N
  skin_temp             float32 [T_aux]   10 Hz, °C
  skin_humidity         float32 [T_aux]   10 Hz, %RH
  events.json           # grasp_onset, release timestamps
  calibration.json      # per-wearer force model

Pilots

Pilots start November 2026.

We train a policy on your sessions with and without force, so your buyers see the difference.

Limited spots in the first cohort.